Part Number Hot Search : 
NTE2551 CXA2039 PMST5550 ADM708S 68HC05B6 MUR8100 H11F1M CJ33A
Product Description
Full Text Search
 

To Download SCN-2K0-05 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 2000W Single Output With Parallel Function
Features :
SCN-2K0
series
AC input 200~260VAC,3 3wires(other system available) Protections: Short circuit / Overload / Over voltage / Over temp. High reliability; Low ripple noise Built-in remote sense function Built-in remote ON-OFF control Built-in parallel operation function Can adjust from 20~100% output voltage by external control 1-5V Forced air cooling by built-in DC fan Case coating with paint 2 years warranty
SPECIFICATION
ORDER NO. SAFETY MODEL NO. DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT (max.) LEAKAGE CURRENT (max.) OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC
(Note. 4)
SCN-2K0-05 2K0S-N005 5V 250A 0 ~ 250A 1250W
SCN-2K0-12 2K0S-N012 12V 167A 0 ~ 167A 2004W 180mVp-p
SCN-2K0-15 2K0S-N015 15V 134A 0 ~ 134A 2010W 200mVp-p
SCN-2K0-24 2K0S-N024 24V 83.5A 0 ~ 83.5A 2004W 240mVp-p
SCN-2K0-48 2K0S-N048 48V 42A 0 ~ 42A 2016W 480mVp-p 1.0% 0.5% 0.5%
RIPPLE & NOISE (max.) Note.2 150mVp-p
5.0% typical adjustment by potentiometer 3.0% 2.0% 0.5% 2.5% 0.5% 1.5%
20~100% adjustment by 1~5VDC external control 2.0% 1.0% 0.5% 1.5% 0.5% 0.5%
SETUP, RISE, HOLD UP TIME 800ms, 50ms, 16ms at full load 200 ~ 260VAC, 3 , 3wires 47 ~ 63Hz 78% 10A / 230VAC 120A / 230VAC 5mA/ 240VAC 110 ~ 135% rated output power Protection type : Current limiting, delay shut down o/p voltage, re-power on to recover 110 ~ 135% follow to output set up point Protection type : Shut down o/p voltage, re-power on to recover >100 / measure by heat sink, near transformer Protection type : Shut down o/p voltage, re-power on to recover -10 ~ +65 (Refer to output load derating curve) 20% ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.04% / (0 ~ 50 ) 10 ~ 200Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes Design refer to UL1950, CSA22.2, IEC60950 I/P-O/P:1500VAC, I/P-FG:1500VAC I/P-O/P, I/P-FG, >100M Ohms / 500VDC / 25 ------30khrs min. MIL-HDBK-217F (25 ) / 70% RH 84% 84% 85% 86%
ISOLATION RESISTANCE HARMONIC CURRENT EMS IMMUNITY MTBF
EMI CONDUCTION & RADIATION Design refer to FCC part 15 class A
OTHERS
DIMENSION PACKING SPECIAL FUNCTION
320*212*134mm (L*W*H) 9.0kg; 1pcs/ 10kg / CARTON DC voltage adj., Remote sensing, remote control, parallel operation (refer to terminal instruction manual)
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. 2.Tolerence: includes set up tolerance, line regulation, load regulation. 3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
File Name:SCN-2K0-SPEC 2007-11-01
2000W Single Output With Parallel Function
Mechanical Specification
SCN-2K0
series
134
320.0
Air flow direction
Air flow direction
10-M3X0.5 TERMINAL BLOCK 4M4X0.7 TERMINAL BLOCK FOR CONTROL SIGNAL FOR 3 3W AC INPUT
212
6-M6 SCREW FOR DC OUTPUT
6 TYP.
30 MAX.
180
4-M4X0.7 MOUNTING HOLE FOR USER 290 12
Derating Curve
External DC Control VS Output Voltage
Vout
O.V.P.
100
100
OUTPUT VOLTAGE (%)
80
LOAD (%)
non-linear
60 40
50
20
-10
0
10
20
30
40
50
60
V 1 2 3 4 5
Ta (
)
EXTERNAL VOLTAGE(Typical)
File Name:SCN-2K0-SPEC 2007-11-01
2000W Single Output With Parallel Function
Control terminal instruction manual
SCN-2K0
series
LOAD
LOAD
LOAD
M+ VS+ VSMVCI VCO GND PAR GND INH
M+ VS+ VSMVCI VCO GND PAR GND INH
M+ VS+ VSMVCI VCO GND PAR GND INH
H:ON L:DFF
USING INTERNAL VOLTAGE CONTROL
ON/OFF CONTROL SWITCH
ON/OFF CONTROL BY TRANSISTOR
LOAD
M+ VS+ VSMVCI VCO GND PAR GND INH
M+ VS+ VSMVCI VCO GND PAR GND INH
DC1-5V
REMOTE SENSING
OUTPUT VOLTAGE ADJUST WITH DC 1-5V
LOAD
LOAD
M+ VS+ VSMVCI VCO GND PAR GND INH
M+ VS+ VSMVCI VCO GND PAR GND INH
M+ VS+ VSMVCI VCO GND PAR GND INH
M+ VS+ VSMVCI VCO GND PAR GND INH
M+ VS+ VSMVCI VCO GND PAR GND INH
M+ VS+ VSMVCI VCO GND PAR GND INH
PARALLEL OPERATION WITH REMOTE SENEING
PARALLEL OPERATION
File Name:SCN-2K0-SPEC 2007-11-01
2000W Single Output With Parallel Function
FIG. A: 33W 220VAC SYSTEM (STANDARD MODEL FOR STOCK)
R R
SCN-2K0
series
L1 N1
FG1
220V
S
L2 N2
FG2
T S N (NC)
L3 N3
FG3
220V
FG T
FIG. B: 1220VAC SYSTEM
L R L1 N1 S FG1
220V
L2 N2
FG2
T N
L3 N3
FG3
N
FG
FIG. C: 34W 220/380VAC SYSTEM
R R L1 N1
FG1
220V
S
L2 N2
FG2
T N N S FG
L3 N3
FG3
380V
T
FIG. D: 34W 190/110VAC SYSTEM
R R L1 N1 S N (N.C.) L2 N2 T L3 N3 N (NC)
110V
FG1
FG2
FG3
S
190V
FG T
File Name:SCN-2K0-SPEC 2007-11-01


▲Up To Search▲   

 
Price & Availability of SCN-2K0-05

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X